Equipment Selection
All the advice and equipment you need for reliable pool treatment
Equipment selection check list
| Pool or spa |
POOL |
POOL |
POOL |
SPA |
SPA |
| Pool volume |
>350 Cubic metres |
>200 Cubic metres |
>50 Cubic metres |
>10 Cubic metres |
>1 Cubic metres |
| Controller |
TEC 2000 |
TEC 2000 |
TEC 2000/750 |
TEC 2000 |
TEC 2000/750 |
Dosing pumps
Dry acid (Na HS04) 10% Incoming calcium hardness and alkalinity are above 100ppm
| Day tank size in litres(+110% bund) |
300 |
200 |
100 |
50 |
50 |
| Agitator |
Manual |
Manual |
Manual |
Manual |
Manual |
Pump model (inc 4 function valve) |
B145 |
PO65 |
PO65 |
PO55 |
PO55 |
| Injector type |
LMI |
LMI |
LMI |
LMI |
LMI |
| Dosing hose size (O.D) |
1/2" |
3/8" |
3/8" |
3/8" |
3/8" |
Sodium hypochlorite (Na 0CL) 10-14% Incoming calcium hardness and alkalinity are above 100ppm
| Day tank size in litres(+110% bund) |
300 |
200 |
100 |
50 |
50 |
| Agitator |
No |
No |
No |
No |
No |
| Hand transfer pump |
Yes |
Yes |
Yes |
Yes |
Yes |
Pump model (inc 4 function valve) |
B145 |
PO65 |
PO65 |
PO55 |
PO55 |
| Injector type |
LMI |
LMI |
LMI |
LMI |
LMI |
| Dosing hose size (O.D) |
1/2" |
3/8" |
3/8" |
3/8" |
3/8" |
Calcium hypochlorite (Ca OCL2) 3% Incoming calcium hardness and alkalinity are above 100ppm
| Day tank size in litres(+110% bund) |
500 |
300 |
200 |
100 |
100 |
| Agitator |
Electric |
Electric |
Electric |
Electric |
Electric |
Pump model (inc 4 function valve) |
B145 |
B145 |
PO65 |
PO65 |
PO55 |
| Injector type |
Rod |
Rod |
Rod |
Rod |
Rod |
| Dosing hose size (O.D) |
1/2" |
1/2" |
3/8" |
3/8" |
3/8" |
Carbon dioxide (CO2) Incoming calcium hardness and alkalinity are above 100ppm
CO2 detector must be used if plant room is below ground level
| CO2 correction system |
Topline |
Topline |
Topline |
Topline |
Topline |
In addition to the above guide, consideration should be given to hydrochloric acid (It does not increase sulphate in pool water) when high bathing loads are expected. Consideration should also be given to dual dosing with CO2 and acid if the alkalinity of the water is unstable.